fix(engine-core): connect to QE binary by IPv4 loopback address #10211
+2
−2
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Unless a different IP or hostname is specified using the
--host
command-line option, the query engine server binds to
127.0.0.1
:The BinaryEngine client tried to connect to the query engine server
using the
localhost
hostname, which normally resolves to either127.0.0.1
or::1
(and in exotic cases might even resolve tosomething completely different). When
localhost
resolved to the IPv6loopback address (which seems to be usually the case with Node.js 17),
the client couldn't connect because the query engine server doesn't bind
to it. This commit changes
localhost
to127.0.0.1
to avoid thiserror.
Fixes #9903