Skip to content

This repository contains the implementation of a deep learning model designed to detect radiolucent foreign body aspiration (FBA) in chest CT scans. Radiolucent FBAs, which are often invisible on conventional radiographs, pose significant diagnostic challenges. Our approach combines airway segmentation with a classification model.

Notifications You must be signed in to change notification settings

ZheChen1999/FBA_DL

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

13 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Automated Detection of Radiolucent Foreign Body Aspiration on Chest CT Using Deep Learning

License: CC BY 4.0

📘 Paper (npj Digital Medicine, under revision)

Radiolucent foreign body aspiration (FBA) is challenging to diagnose due to its subtle imaging characteristics on CT. We present a deep learning pipeline that integrates 3D airway segmentation with multi-view classification. Our model was validated across three independent hospital datasets and outperformed expert radiologists in key diagnostic metrics.


🔍 Overview

  • Segmentation: MedpSeg, a high-precision 3D U-Net-based segmentation model.
  • Classification: ResNet-18 applied to 12-view 2D projections of the airway tree.
  • Validation: Multi-center datasets from three hospitals in Wuhan, China.
  • Comparison: Model demonstrated higher recall and F1 score than radiologists.

📊 Performance Summary

Dataset Accuracy Precision Recall F1 Score
Internal Modeling (n=268) 94.4% 84.2% 78.0% 81.0%
External Validation (n=103) 90.3% 76.2% 76.2% 76.2%
Independent Evaluation (n=70) 90.0% 76.9% 71.4% 74.1%
Expert Radiologists 87.1% 100% 35.7% 52.6%

⚙️ Installation

Requires Python 3.8+, PyTorch 1.10+

git clone https://github.com/ZheChen1999/FBA_DL.git
cd FBA_DL
pip install -r requirements.txt

🧠 Technical Highlights

  • Airway segmentation: 3D U-Net (MedpSeg) with expert-in-the-loop refinement
  • Snapshot generation: Multi-angle 2D views of 3D segmented airway
  • Classification: ResNet-18 with Focal Loss and data augmentation
  • Training strategy: 5-fold cross-validation, early stopping
  • Hardware: Dual RTX A5000 GPUs for segmentation

🏥 Clinical Workflow

  1. Initial CXR (to rule out radiopaque FBA)
  2. Chest CT if radiolucent FBA suspected
  3. AI-assisted segmentation and classification
  4. Use model results to prioritize bronchoscopy

📘 Citation

@article{liu2025fba,
  title={Automated Detection of Radiolucent Foreign Body Aspiration on Chest CT Using Deep Learning},
  author={Liu, Xiaofan and Chen, Zhe and Tang, Zhiyong and Yang, Xun and Jiang, Yan and et al.},
  journal={npj Digital Medicine},
  year={2025},
  note={Under review}
}

📂 Supplementary Materials

Detailed methodology, datasets, training protocols, and ablation studies are provided in the Supplementary Materials. Topics include:

  • Data Sources: Multi-center cohorts from Wuhan hospitals + ATM22 dataset
  • MedpSeg Architecture: 3D U-Net with expert-guided iterative training
  • ResNet-18 Classifier: Multi-view CNN with snapshot-based classification
  • Evaluation: AUC, precision, recall, F1, cross-validation, DeLong's test
  • Ablation Studies: Contribution of each pipeline component
  • Backbone Comparisons: DenseNet, ViT-B/16, Swin-T, etc.

📈 Additional Results

Table S3: Backbone Architecture Comparison in Independent Evaluation Cohort

Backbone TP FN TN FP Accuracy Precision Recall F1 Score
ResNet-18 10 (14.3%) 4 (5.7%) 53 (75.7%) 3 (4.3%) 90.0% 76.9% 71.4% 74.1%
EfficientNet-B0 9 (12.9%) 5 (7.1%) 53 (75.7%) 3 (4.3%) 88.6% 75.0% 64.3% 69.2%
DenseNet-121 9 (12.9%) 5 (7.1%) 52 (74.3%) 4 (5.7%) 87.1% 69.2% 64.3% 66.7%
ViT-B/16 8 (11.4%) 6 (8.6%) 52 (74.3%) 4 (5.7%) 85.7% 66.7% 57.1% 61.5%
Swin-T (tiny) 9 (12.9%) 5 (7.1%) 51 (72.9%) 5 (7.1%) 85.7% 64.3% 64.3% 64.3%

Interpretation: The full pipeline achieved the highest performance across all evaluation metrics, validating the importance of each module. These findings suggest that structural modeling and comprehensive spatial coverage are critical for detecting subtle FBA-related changes.


Table S4: Age-based Subgroup Performance in Independent Evaluation Cohort

Age Group TP FN TN FP Accuracy Precision Recall F1 Score
< 40 years (n=12) 3 (25.0%) 1 (8.3%) 7 (58.3%) 1 (8.3%) 83.3% 75.0% 75.0% 75.0%
≥ 40 years (n=58) 7 (12.1%) 3 (5.2%) 46 (79.3%) 2 (3.4%) 91.4% 77.8% 70.0% 73.7%

All P values were calculated using Fisher’s exact test.


Table S5: Ablation Study in Independent Evaluation Cohort

Variant TP FN TN FP Accuracy Precision Recall F1 Score
Baseline (Raw CT Only) 8 (11.4%) 6 (8.6%) 43 (61.4%) 13 (18.6%) 72.9% 38.1% 57.1% 45.7%
+ With Segmentation Mask 9 (12.9%) 5 (7.1%) 45 (64.3%) 11 (15.7%) 77.1% 45.0% 64.3% 52.9%
+ Fewer Views (6 Views) 9 (12.9%) 5 (7.1%) 47 (67.1%) 9 (12.9%) 80.0% 50.0% 64.3% 56.3%
+ With Data Augmentation 10 (14.3%) 4 (5.7%) 49 (70.0%) 7 (10.0%) 84.3% 58.8% 71.4% 64.5%
Full Pipeline (12 Views) 10 (14.3%) 4 (5.7%) 53 (75.7%) 3 (4.3%) 90.0% 76.9% 71.4% 74.1%

Interpretation: The full pipeline achieved the highest performance across all evaluation metrics, validating the importance of each module. These findings suggest that structural modeling and comprehensive spatial coverage are critical for detecting subtle FBA-related changes.


Table S6: Parameter Summary Table

Component Parameter/Setting
CT Preprocessing HU clipping: –1000 to +400; isotropic voxel size: 1.0 mm³
Intensity Normalization Min–max scaling to [0, 1]
Segmentation Architecture MedpSeg (3D U-Net + attention + residual blocks)
Training Optimizer Adam, LR: 1×10⁻⁴, weight decay: 1×10⁻⁵, batch size: 16
Loss Function Focal Loss
Snapshot Rendering 12 views, camera distance: 150 mm, resolution: 224×224
Classification Backbone ResNet-18 (best), with comparison to DenseNet, Swin-T, etc.
Classification Optimizer Adam, LR: 1×10⁻⁴ with scheduler, batch size: 16
Loss Function Focal loss (α = 0.25, γ = 2.0)
Validation Strategy 5-fold cross-validation, early stopping (patience = 10)
Inference Pipeline Fully automated for segmentation and classification
Reproducibility Tools Code and configs available at: github.com/ZheChen1999/FBA_DL

In summary: This study presents an end-to-end DL pipeline combining high-precision airway segmentation and CT-based classification to detect radiolucent FBA. The model generalizes well across multiple cohorts and offers clinically meaningful improvements over expert interpretation in precision, highlighting its potential as a second-reader and triage aid in complex diagnostic settings.

📜 License

This project is licensed under the Creative Commons Attribution 4.0 International (CC BY 4.0).


🔗 Related Links


For detailed replication instructions, data access requests, or collaboration inquiries, please contact the corresponding authors.

About

This repository contains the implementation of a deep learning model designed to detect radiolucent foreign body aspiration (FBA) in chest CT scans. Radiolucent FBAs, which are often invisible on conventional radiographs, pose significant diagnostic challenges. Our approach combines airway segmentation with a classification model.

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages